Technical Specifications
Mains Voltage: 110/240VAC
Mains Frequency: 50/60Hz
Power Factor: >0.98
Efficiency: >90%
Operating Frequency: 40-60KHz
Dimensions: 185*56*38mm
Lamp status indication via LED indication
Green LED: lamp on
Red LED: lamp fault
Lamp status forwarding
Potential free relay contacts for lamp on/lamp fault.
Installation Requirement
Wire Gauge: 0.5-1.5mm2
Max. cable length between ballasts and lamp: 5m
Relay contacts: potential free, load: 50…500mA at 24…230V AC;
50…500mA at 5…60V DC
Mounting Restrictions
Disconnect Input Power Before Installing or Servicing.
Ballast Case Must Be Grounded.
Don’t short any two wires of the four outputs.
Features
Starting: Preheat
Add buzzer function
Buzzer function: the buzzer will sound when the lamp fault
UV lamp can be connected to external LED.
Applications
All areas of applications include UV lamps.
Air purification
Industrial water treatment
Kitchen purification
Type |
Input Voltage (V) |
Input Power (W) |
Input Current (A) |
Power Per Lamp (W) |
Lamp Current (A) |
Weight (kg) |
PA7-1200-105U |
99-264 |
49-119 |
1.10A@110V 0.50A@240V |
42-105 |
1.10-1.30 |
0.27 |