Technical Specifications
Mains Voltage: 230VAC
Mains Frequency: 50/60Hz
Power Factor: >0.98
Efficiency: >94%
Operating Frequency: 40-60KHz
Dimensions: 250*141*50mm
Lamp status indication via LED indication
Green LED: lamp on
Red LED: lamp fault
Lamp status forwarding
Potential free relay contacts for lamp on/lamp fault.
Installation Requirement
Wire Gauge: 1.0-1.5mm2
Max. cable length between ballasts and lamp: 5m
Relay contacts: potential free, load: 50…500mA at 24…230V AC;
50…500mA at 5…60V DC
Mounting Restrictions
Disconnect Input Power Before Installing or Servicing.
Ballast Case Must Be Grounded.
Don’t short any two wires of the four outputs.
Features
Starting: Preheat
Applications
All areas of applications include UV lamps.
Industrial water treatment
Municipal water treatment
Water injection for oilfield
Equivalent UV Germicidal Replacement Chiyoda kohan CZ221 UV Ballast
Type |
Input Voltage (V) |
Input Power (W) |
Input Current (A) |
Power Per Lamp (W) |
Lamp Current (A) |
Weight (kg) |
CZ221 |
198-264 |
692 |
3.07A |
2*320 |
1.8-2.2 |
1.17 |