CZ221 Chiyoda kohan UV Ballast $182



CZ221 Chiyoda kohan UV Ballast $182

$182.00




Product Info & Specifications

Technical Specifications

Mains Voltage: 230VAC

Mains Frequency: 50/60Hz

Power Factor: >0.98

Efficiency: >94%

Operating Frequency: 40-60KHz

Dimensions: 250*141*50mm

Lamp status indication via LED indication

Green LED: lamp on

Red LED: lamp fault

Lamp status forwarding

Potential free relay contacts for lamp on/lamp fault.

Installation Requirement

Wire Gauge: 1.0-1.5mm2

Max. cable length between ballasts and lamp: 5m

Relay contacts: potential free, load: 50…500mA at 24…230V AC;

                                50…500mA at 5…60V DC

Mounting Restrictions

Disconnect Input Power Before Installing or Servicing.

Ballast Case Must Be Grounded.

Don’t short any two wires of the four outputs.

Features

Starting: Preheat

Applications

All areas of applications include UV lamps.

Industrial water treatment

Municipal water treatment

Water injection for oilfield

 Equivalent UV Germicidal Replacement Chiyoda kohan CZ221 UV Ballast

Type

Input Voltage (V)

Input Power

(W)

Input Current (A)

Power Per Lamp

(W)

Lamp Current (A)

Weight (kg)

CZ221

198-264

692

3.07A

2*320

1.8-2.2

1.17