10-0116 Atlantic Ultraviolet uv Electronic Ballast $82



10-0116 Atlantic Ultraviolet uv Electronic Ballast $82

$82.00




Product Info & Specifications

Replacement 220V/50Hz Transformer Ballast for Atlantic UV Sanitron Series S2400, S5000, S10000, S20000, S25000 in 220/240v 50/60Hz.

Technical Specifications

Mains Voltage: 110/240VAC

Mains Frequency: 50/60Hz

Power Factor: >0.98

Efficiency: >92%

Operating Frequency: 40-60KHz

Dimensions: 250*65*40mm

Lamp status indication via LED indication

Green LED: lamp on

Red LED: lamp fault

Lamp status forwarding

Potential free relay contacts for lamp on/lamp fault.

Installation Requirement

Wire Gauge: 0.5-1.5mm2

Max. cable length between ballasts and lamp: 5m

Relay contacts: potential free, load: 50…500mA at 24…230V AC;

                                50…500mA at 5…60V DC

DC5V±5% 5mA: lamp on.

DC0V: lamp fault or no lamp. Connect LED.

DC5V±10% Max. 50mA: lamp on.

DCOV: lamp fault or no lamp. Connect Relay.

Mounting Restrictions

Disconnect Input Power Before Installing or Servicing.

Ballast Case Must Be Grounded.

Don’t short any two wires of the four outputs.

Features

Starting: Preheat

Applications

All areas of applications include UV lamps.

Air purification

Industrial water treatment

Municipal water treatment

 

Type

Input Voltage (V)

Input Power

(W)

Input Current (A)

Power Per Lamp

(W)

Lamp Current (A)

Weight (kg)

        10-0116

99-264

164

1.50A@110V

0.68A@240V

57-150

1.4-1.6

0.53